TCE series – Multicore audio cable – 26AWG – n x 2 x 0.14 mm?

Features
??Each pair is individually insulated with black and number-printed PVC jacket

??Excellent to work with due to the use of a special AL/PT-foil

??Flexible due to the special wire construction

??Good shielding due to the overall and individual wire pair shielding

Applications
??Reasonable cable for the construction of stage box systems and?multi-pair systems

??Dependable cable for permanent installation in installation technologies

Cable Colour
??Black

Technical Data

Order Code TCE2 TCE4 TCE8
TCE12

PVC jacket, diameter
8.5 mm
10 mm
14 mm
15 mm

Cond. PVC jacket,diameter
3.0 mm
3.0 mm
3.0 mm
3.0 mm

AWG
26
26 26 26
No. of inner conductors
2 x 2 x 0.14 mm?
4 x 2 x 0.14?mm?
8 x 2 x 0.14?mm?
12 x 2 x 0.14?mm?

Copper strand per conductor
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm

Conductor insulation
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm

Shielding

AL/PT-foil + drain wire 7 x 0.15 mm? tin plated copper

AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper

Shielding factor
100 %
100 %
100 %
100 %

Temperature range?
min. -20 ?C
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C

Temperature?range?
max. 70??C
max. 70??C
max. 70??C
max. 70??C

Electrical Data

Capac. cond./cond. per 1 m
66 pF
66 pF
66 pF
66 pF

Capac. cond./shield. per 1 m
140 pF
140 pF
140 pF
140 pF

Cond. resistance per 1 m 126.5 m? 126.5 m? 126.5 m? 126.5 m?

Shield. resistance per 1 m 105.2 m? 105.2 m? 105.2 m? 105.2 m?

Technical Data

Order Code TCE16 TCE20 TCE24
TCE32

PVC jacket, diameter
18 mm
20 mm
22 mm
25 mm

Cond. PVC jacket,diameter
3.0 mm
3.0 mm
3.0 mm
3.0 mm

AWG
26
26 26 26
No. of inner conductors
16 x 2 x 0.14?mm?
20 x 2 x 0.14?mm?
24 x 2 x 0.14?mm?
32 x 2 x 0.14?mm?

Copper strand per conductor
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm

Conductor insulation
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm

Shielding

AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper

AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper
AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper
AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper

Shielding factor
100 %
100 %
100 %
100 %

Temperature range?
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C

Temperature?range?
max. 70??C
max. 70??C
max. 70??C
max. 70??C

Electrical Data

Capac. cond./cond. per 1 m
66 pF
66 pF
66 pF
66 pF

Capac. cond./shield. per 1 m
140 pF
140 pF
140 pF
140 pF

Cond. resistance per 1 m 126.5 m? 126.5 m? 126.5 m? 126.5 m?

Shield. resistance per 1 m 105.2 m? 105.2 m? 105.2 m? 105.2?m?

Technical Data

Order Code TCE40
PVC jacket, diameter
26.7 mm

Cond. PVC jacket,diameter
3.0 mm

AWG
26

No. of inner conductors
40 x 2 x 0.14?mm?

Copper strand per conductor
18 x 0.10 mm

Conductor insulation
PE 1.05 mm

Shielding

AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper

Shielding factor
100 %

Temperature range?
min.?-20 ?C

Temperature?range?
max. 70??C

Electrical Data

Capac. cond./cond. per 1 m
66 pF

Capac. cond./shield. per 1 m
140 pF

Cond. resistance per 1 m 126.5 m?
Shield. resistance per 1 m 105.2 m?

SKU: TCE series Category:

Description

Features
Each pair is individually insulated with black and number-printed PVC jacket

Excellent to work with due to the use of a special AL/PT-foil

Flexible due to the special wire construction

Good shielding due to the overall and individual wire pair shielding


Applications
Reasonable cable for the construction of stage box systems and multi-pair systems

Dependable cable for permanent installation in installation technologies


Cable Colour
Black

Technical Data
Order Code TCE2 TCE4 TCE8 TCE12
PVC jacket, diameter 8.5 mm 10 mm 14 mm 15 mm
Cond. PVC jacket,diameter 3.0 mm 3.0 mm 3.0 mm 3.0 mm
AWG 26 26 26 26
No. of inner conductors 2 x 2 x 0.14 mm? 4 x 2 x 0.14 mm? 8 x 2 x 0.14 mm? 12 x 2 x 0.14 mm?
Copper strand per conductor 18 x 0.10 mm 18 x 0.10 mm 18 x 0.10 mm 18 x 0.10 mm
Conductor insulation PE 1.05 mm PE 1.05 mm PE 1.05 mm PE 1.05 mm
Shielding

AL/PT-foil + drain wire 7 x 0.15 mm  tin plated copper

AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper
Shielding factor 100 % 100 % 100 % 100 %
Temperature range  min. -20 ?C min. -20 ?C min. -20 ?C min. -20 ?C
Temperature range  max. 70 ?C max. 70 ?C max. 70 ?C max. 70 ?C
Electrical Data
Capac. cond./cond. per 1 m 66 pF 66 pF 66 pF 66 pF
Capac. cond./shield. per 1 m 140 pF 140 pF 140 pF 140 pF
Cond. resistance per 1 m 126.5 m? 126.5 m? 126.5 m? 126.5 m?
Shield. resistance per 1 m 105.2 m? 105.2 m? 105.2 m? 105.2 m?

Technical Data
Order Code TCE16 TCE20 TCE24 TCE32
PVC jacket, diameter 18 mm 20 mm 22 mm 25 mm
Cond. PVC jacket,diameter 3.0 mm 3.0 mm 3.0 mm 3.0 mm
AWG 26 26 26 26
No. of inner conductors 16 x 2 x 0.14 mm? 20 x 2 x 0.14 mm? 24 x 2 x 0.14 mm? 32 x 2 x 0.14 mm?
Copper strand per conductor 18 x 0.10 mm 18 x 0.10 mm 18 x 0.10 mm 18 x 0.10 mm
Conductor insulation PE 1.05 mm PE 1.05 mm PE 1.05 mm PE 1.05 mm
Shielding

AL/PT-foil + drain wire  7 x 0.15 mm  tin plated copper

AL/PT-foil + drain wire  7 x 0.15 mm tin plated copper AL/PT-foil + drain wire  7 x 0.15 mm tin plated copper AL/PT-foil + drain wire  7 x 0.15 mm tin plated copper
Shielding factor 100 % 100 % 100 % 100 %
Temperature range  min. -20 ?C min. -20 ?C min. -20 ?C min. -20 ?C
Temperature range  max. 70 ?C max. 70 ?C max. 70 ?C max. 70 ?C
Electrical Data
Capac. cond./cond. per 1 m 66 pF 66 pF 66 pF 66 pF
Capac. cond./shield. per 1 m 140 pF 140 pF 140 pF 140 pF
Cond. resistance per 1 m 126.5 m? 126.5 m? 126.5 m? 126.5 m?
Shield. resistance per 1 m 105.2 m? 105.2 m? 105.2 m? 105.2 m?

Technical Data
Order Code TCE40
PVC jacket, diameter 26.7 mm
Cond. PVC jacket,diameter 3.0 mm
AWG 26
No. of inner conductors 40 x 2 x 0.14 mm?
Copper strand per conductor 18 x 0.10 mm
Conductor insulation PE 1.05 mm
Shielding

AL/PT-foil + drain wire  7 x 0.15 mm  tin plated copper

Shielding factor 100 %
Temperature range  min. -20 ?C
Temperature range  max. 70 ?C
Electrical Data
Capac. cond./cond. per 1 m 66 pF
Capac. cond./shield. per 1 m 140 pF
Cond. resistance per 1 m 126.5 m?
Shield. resistance per 1 m 105.2 m?

Additional information

SIZE

Unit: metre(s)

Reviews

There are no reviews yet.

Be the first to review “TCE series – Multicore audio cable – 26AWG – n x 2 x 0.14 mm?”

Your email address will not be published. Required fields are marked *