Features
??Each pair is individually insulated with coloured and number-printed PVC jacket? ? ? ? ? ??COLOURED
??Excellent to work with due to the use of a special AL/PT-foil
??Flexible due to the special wire construction
??Good shielding due to the overall and individual wire pair shielding
Applications
??Reasonable cable for the construction of stage box systems and?multi-pair systems
??Dependable cable for permanent installation in installation technologies
Cable Colour
??Black
Technical Data
Order Code TCE2C TCE4C TCE8C
TCE12C
PVC jacket, diameter
8.5 mm
10 mm
14 mm
15 mm
Cond. PVC jacket,diameter
3.0 mm
3.0 mm
3.0 mm
3.0 mm
AWG
26
26 26 26
No. of inner conductors
8 x 2 x 0.14 mm?
4 x 2 x 0.14?mm?
8 x 2 x 0.14?mm?
12 x 2 x 0.14?mm?
Copper strand per conductor
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
Conductor insulation
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
Shielding
AL/PT-foil + drain wire 7 x 0.15 mm? tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
Shielding factor
100 %
100 %
100 %
100 %
Temperature range?
min. -20 ?C
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C
Temperature?range?
max. 70??C
max. 70??C
max. 70??C
max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
66 pF
66 pF
66 pF
66 pF
Capac. cond./shield. per 1 m
140 pF
140 pF
140 pF
140 pF
Cond. resistance per 1 m 126.5 m? 126.5 m? 126.5 m? 126.5 m?
Shield. resistance per 1 m 105.2 m? 105.2 m? 105.2 m? 105.2 m?
Technical Data
Order Code TCE16C TCE20C TCE24C
PVC jacket, diameter
18 mm
20 mm
22 mm
Cond. PVC jacket,diameter
3.0 mm
3.0 mm
3.0 mm
AWG
26
26 26
No. of inner conductors
16 x 2 x 0.14?mm?
20 x 2 x 0.14?mm?
24 x 2 x 0.14?mm?
Copper strand per conductor
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
Conductor insulation
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
Shielding
AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper
AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper
AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper
Shielding factor
100 %
100 %
100 %
Temperature range?
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C
Temperature?range?
max. 70??C
max. 70??C
max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
66 pF
66 pF
66 pF
Capac. cond./shield. per 1 m
140 pF
140 pF
140 pF
Cond. resistance per 1 m 126.5 m? 126.5 m? 126.5 m?
Shield. resistance per 1 m 105.2 m? 105.2 m? 105.2 m?
Features? ???
??Compact diameter? Compact diameter
? Excellent to work with due to the use of a special AL/PT-foil
? Flexible due to the special wire construction
? Good shielding due to the overall and individual wire pair shielding
Applications
??Reasonable cable for the construction of stage box systems and multi-pair systems
? Dependable cable for permanent installation in installation technologies
Cable Colour
??Black
Technical Data
Order Code TCF4 TCF8
PVC jacket, diameter
8.0 mm
10.2 mm
AWG
24
24
No. of inner conductors
4 x 2 x 0.22?mm?
8 x 2 x 0.22?mm?
Copper strand per conductor
28 x 0.10 mm
28 x 0.10 mm
Conductor insulation
PE 1.2 mm
PE 1.2 mm
Shielding
AL/PT-foil + drain wire??7 x 0.15 mm? tin plated copper
AL/PT-foil + drain wire? 7 x?0.15 mm tin plated copper
Shielding factor
100 %
100 %
Temperature range?
min. -20 ?C
min.?-20 ?C
Temperature?range?
max. 70??C
max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
61 pF
61 pF
Capac. cond./shield. per 1 m
125 pF
125 pF
Cond. resistance per 1 m 78 m? 78 m?
Shield. resistance per 1 m 105 m? 105 m?
?
Features
??Each pair is individually insulated with black and number-printed PVC jacket
??Excellent to work with due to the use of a special AL/PT-foil
??Flexible due to the special wire construction
??Good shielding due to the overall and individual wire pair shielding
Applications
??Reasonable cable for the construction of stage box systems and?multi-pair systems
??Dependable cable for permanent installation in installation technologies
Cable Colour
??Black
Technical Data
Order Code TCG4 TCG8
PVC jacket, diameter
10.5 mm
15 mm
Cond. PVC jacket,diameter
3.2 mm
3.2 mm
AWG
24 24
No. of inner conductors
4 x 2 x 0.22?mm?
8 x 2 x 0.22?mm?
Copper strand per conductor
28 x 0.10 mm
28 x 0.10 mm
Conductor insulation
PE 1.2 mm
PE 1.2 mm
Shielding
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
Shielding factor
100 %
100 %
Temperature range?
min.?-20 ?C
min.?-20 ?C
Temperature?range?
max. 70??C
max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
70 pF
70 pF
Capac. cond./shield. per 1 m
147 pF
147 pF
Cond. resistance per 1 m 80 m? 80 m?
Shield. resistance per 1 m 100 m? 100 m?
Features? ???
??Compact diameter
??Excellent to work with due to the use of a special AL/PT-foil
??Flexible due to the special wire construction
??Good shielding due to the overall and individual wire pair shielding
??Very good pricing
Applications
??Reasonable cable for the construction of stage box systems and?multi-pair systems
??Dependable cable for permanent installation in installation technologies
Cable Colour
??Black
Technical Data
Order Code TCC8 TCC12 TCC16
TCC20
PVC jacket, diameter
9.5 mm
11.5 mm
13.5 mm
14.5 mm
AWG
26
26 26 26
No. of inner conductors
8 x 2 x 0.14 mm?
12 x 2 x 0.14?mm?
16 x 2 x 0.14?mm?
20 x 2 x 0.14?mm?
Copper strand per conductor
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
Conductor insulation
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
Shielding
AL/PT-foil + drain wire 7 x 0.15 mm? tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
Shielding factor
100 %
100 %
100 %
100 %
Temperature range?
min. -20 ?C
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C
Temperature?range?
max. 70??C
max. 70??C
max. 70??C
max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
65 pF
65 pF
65 pF
65 pF
Capac. cond./shield. per 1 m
130 pF
130 pF
130 pF
130 pF
Cond. resistance per 1 m 125 m? 125 m? 125 m? 125 m?
Shield. resistance per 1 m 110 m? 110 m? 110 m? 110 m?
Technical Data
Order Code TCC24 TCC32 TCC40
PVC jacket, diameter
16 mm
18 mm
20 mm
AWG
26
26 26
No. of inner conductors
24 x 2 x 0.14?mm?
32 x 2 x 0.14?mm?
40 x 2 x 0.14?mm?
Copper strand per conductor
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
Conductor insulation
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
Shielding
AL/PT-foil + drain wire? 7 x 0.15 mm? ?tin plated copper
AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper
AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper
Shielding factor
100 %
100 %
100 %
Temperature range?
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C
Temperature?range?
max. 70??C
max. 70??C
max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
65 pF
65 pF
65 pF
Capac. cond./shield. per 1 m
130 pF
130 pF
130 pF
Cond. resistance per 1 m 125 m? 125 m? 125 m?
Shield. resistance per 1 m 110 m? 110 m? 110 m?
Features
??Each pair is individually insulated with black and number-printed PVC jacket
??Excellent to work with due to the use of a special AL/PT-foil
??Flexible due to the special wire construction
??Good shielding due to the overall and individual wire pair shielding
Applications
??Reasonable cable for the construction of stage box systems and?multi-pair systems
??Dependable cable for permanent installation in installation technologies
Cable Colour
??Black
Technical Data
Order Code TCE2 TCE4 TCE8
TCE12
PVC jacket, diameter
8.5 mm
10 mm
14 mm
15 mm
Cond. PVC jacket,diameter
3.0 mm
3.0 mm
3.0 mm
3.0 mm
AWG
26
26 26 26
No. of inner conductors
2 x 2 x 0.14 mm?
4 x 2 x 0.14?mm?
8 x 2 x 0.14?mm?
12 x 2 x 0.14?mm?
Copper strand per conductor
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
Conductor insulation
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
Shielding
AL/PT-foil + drain wire 7 x 0.15 mm? tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
Shielding factor
100 %
100 %
100 %
100 %
Temperature range?
min. -20 ?C
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C
Temperature?range?
max. 70??C
max. 70??C
max. 70??C
max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
66 pF
66 pF
66 pF
66 pF
Capac. cond./shield. per 1 m
140 pF
140 pF
140 pF
140 pF
Cond. resistance per 1 m 126.5 m? 126.5 m? 126.5 m? 126.5 m?
Shield. resistance per 1 m 105.2 m? 105.2 m? 105.2 m? 105.2 m?
Technical Data
Order Code TCE16 TCE20 TCE24
TCE32
PVC jacket, diameter
18 mm
20 mm
22 mm
25 mm
Cond. PVC jacket,diameter
3.0 mm
3.0 mm
3.0 mm
3.0 mm
AWG
26
26 26 26
No. of inner conductors
16 x 2 x 0.14?mm?
20 x 2 x 0.14?mm?
24 x 2 x 0.14?mm?
32 x 2 x 0.14?mm?
Copper strand per conductor
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
18 x 0.10 mm
Conductor insulation
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
PE 1.05 mm
Shielding
AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper
AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper
AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper
AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper
Shielding factor
100 %
100 %
100 %
100 %
Temperature range?
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C
min.?-20 ?C
Temperature?range?
max. 70??C
max. 70??C
max. 70??C
max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
66 pF
66 pF
66 pF
66 pF
Capac. cond./shield. per 1 m
140 pF
140 pF
140 pF
140 pF
Cond. resistance per 1 m 126.5 m? 126.5 m? 126.5 m? 126.5 m?
Shield. resistance per 1 m 105.2 m? 105.2 m? 105.2 m? 105.2?m?
Technical Data
Order Code TCE40
PVC jacket, diameter
26.7 mm
Cond. PVC jacket,diameter
3.0 mm
AWG
26
No. of inner conductors
40 x 2 x 0.14?mm?
Copper strand per conductor
18 x 0.10 mm
Conductor insulation
PE 1.05 mm
Shielding
AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper
Shielding factor
100 %
Temperature range?
min.?-20 ?C
Temperature?range?
max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
66 pF
Capac. cond./shield. per 1 m
140 pF
Cond. resistance per 1 m 126.5 m?
Shield. resistance per 1 m 105.2 m?