Features
??Each pair is individually insulated with coloured and number-printed PVC jacket? ? ? ? ? ??COLOURED
??Excellent to work with due to the use of a special AL/PT-foil
??Flexible due to the special wire construction
??Good shielding due to the overall and individual wire pair shielding
Applications
??Reasonable cable for the construction of stage box systems and?multi-pair systems
??Dependable cable for permanent installation in installation technologies
Cable Colour
??Black
Technical Data
Order Code	TCE2C	TCE4C	TCE8C
	TCE12C
PVC jacket, diameter
	8.5 mm
	10 mm
	14 mm
	15 mm
Cond. PVC jacket,diameter
	3.0 mm
	3.0 mm
	3.0 mm
	3.0 mm
AWG
	26
	26	26	26
No. of inner conductors
	8 x 2 x 0.14 mm?
	4 x 2 x 0.14?mm?
	8 x 2 x 0.14?mm?
	12 x 2 x 0.14?mm?
Copper strand per conductor
	18 x 0.10 mm
	18 x 0.10 mm
	18 x 0.10 mm
	18 x 0.10 mm
Conductor insulation
	PE 1.05 mm
	PE 1.05 mm
	PE 1.05 mm
	PE 1.05 mm
Shielding
AL/PT-foil + drain wire 7 x 0.15 mm? tin plated copper
	AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
	AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
	AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
Shielding factor
	100 %
	100 %
	100 %
	100 %
Temperature range?
	min. -20 ?C
	min.?-20 ?C
	min.?-20 ?C
	min.?-20 ?C
Temperature?range?
	max. 70??C
	max. 70??C
	max. 70??C
	max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
	66 pF
	66 pF
	66 pF
	66 pF
Capac. cond./shield. per 1 m
	140 pF
	140 pF
	140 pF
	140 pF
Cond. resistance per 1 m 126.5 m? 126.5 m? 126.5 m? 126.5 m?
Shield. resistance per 1 m 105.2 m? 105.2 m? 105.2 m? 105.2 m?
Technical Data
Order Code TCE16C TCE20C TCE24C
PVC jacket, diameter
	18 mm
	20 mm
	22 mm
Cond. PVC jacket,diameter
	3.0 mm
	3.0 mm
	3.0 mm
AWG
	26
	26	26
No. of inner conductors
	16 x 2 x 0.14?mm?
	20 x 2 x 0.14?mm?
	24 x 2 x 0.14?mm?
Copper strand per conductor
	18 x 0.10 mm
	18 x 0.10 mm
	18 x 0.10 mm
Conductor insulation
	PE 1.05 mm
	PE 1.05 mm
	PE 1.05 mm
Shielding
AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper
	AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper
	AL/PT-foil + drain wire? 7 x 0.15 mm tin plated copper
Shielding factor
	100 %
	100 %
	100 %
Temperature range?
	min.?-20 ?C
	min.?-20 ?C
	min.?-20 ?C
Temperature?range?
	max. 70??C
	max. 70??C
	max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
	66 pF
	66 pF
	66 pF
Capac. cond./shield. per 1 m
	140 pF
	140 pF
	140 pF
Cond. resistance per 1 m	126.5 m?	126.5 m?	126.5 m?
Shield. resistance per 1 m	105.2 m?	105.2 m?	105.2 m?
	Features
? Each pair is individually insulated with coloured and number-printed PVC jacket            COLOURED
? Excellent to work with due to the use of a special AL/PT-foil
? Flexible due to the special wire construction
? Good shielding due to the overall and individual wire pair shielding
	
	Applications
? Reasonable cable for the construction of stage box systems and multi-pair systems
? Dependable cable for permanent installation in installation technologies
	
	Cable Colour
? Black
| Technical Data | ||||
| Order Code | TCE2C | TCE4C | TCE8C | TCE12C | 
| PVC jacket, diameter | 8.5 mm | 10 mm | 14 mm | 15 mm | 
| Cond. PVC jacket,diameter | 3.0 mm | 3.0 mm | 3.0 mm | 3.0 mm | 
| AWG | 26 | 26 | 26 | 26 | 
| No. of inner conductors | 8 x 2 x 0.14 mm? | 4 x 2 x 0.14 mm? | 8 x 2 x 0.14 mm? | 12 x 2 x 0.14 mm? | 
| Copper strand per conductor | 18 x 0.10 mm | 18 x 0.10 mm | 18 x 0.10 mm | 18 x 0.10 mm | 
| Conductor insulation | PE 1.05 mm | PE 1.05 mm | PE 1.05 mm | PE 1.05 mm | 
| Shielding | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | 
| Shielding factor | 100 % | 100 % | 100 % | 100 % | 
| Temperature range | min. -20 ?C | min. -20 ?C | min. -20 ?C | min. -20 ?C | 
| Temperature range | max. 70 ?C | max. 70 ?C | max. 70 ?C | max. 70 ?C | 
| Electrical Data | ||||
| Capac. cond./cond. per 1 m | 66 pF | 66 pF | 66 pF | 66 pF | 
| Capac. cond./shield. per 1 m | 140 pF | 140 pF | 140 pF | 140 pF | 
| Cond. resistance per 1 m | 126.5 m? | 126.5 m? | 126.5 m? | 126.5 m? | 
| Shield. resistance per 1 m | 105.2 m? | 105.2 m? | 105.2 m? | 105.2 m? | 
| Technical Data | |||
| Order Code | TCE16C | TCE20C | TCE24C | 
| PVC jacket, diameter | 18 mm | 20 mm | 22 mm | 
| Cond. PVC jacket,diameter | 3.0 mm | 3.0 mm | 3.0 mm | 
| AWG | 26 | 26 | 26 | 
| No. of inner conductors | 16 x 2 x 0.14 mm? | 20 x 2 x 0.14 mm? | 24 x 2 x 0.14 mm? | 
| Copper strand per conductor | 18 x 0.10 mm | 18 x 0.10 mm | 18 x 0.10 mm | 
| Conductor insulation | PE 1.05 mm | PE 1.05 mm | PE 1.05 mm | 
| Shielding | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | 
| Shielding factor | 100 % | 100 % | 100 % | 
| Temperature range | min. -20 ?C | min. -20 ?C | min. -20 ?C | 
| Temperature range | max. 70 ?C | max. 70 ?C | max. 70 ?C | 
| Electrical Data | |||
| Capac. cond./cond. per 1 m | 66 pF | 66 pF | 66 pF | 
| Capac. cond./shield. per 1 m | 140 pF | 140 pF | 140 pF | 
| Cond. resistance per 1 m | 126.5 m? | 126.5 m? | 126.5 m? | 
| Shield. resistance per 1 m | 105.2 m? | 105.2 m? | 105.2 m? | 
| SIZE | Unit: metre(s) | 
|---|
Reviews