Subscribe Now and Get Discount 10%
Error: Contact form not found.
Error: Contact form not found.
 
								 
								Features? ???
??Compact diameter
??Excellent to work with due to the use of a special AL/PT-foil
??Flexible due to the special wire construction
??Good shielding due to the overall and individual wire pair shielding
??Very good pricing
Applications
??Reasonable cable for the construction of stage box systems and?multi-pair systems
??Dependable cable for permanent installation in installation technologies
Cable Colour
??Black
Technical Data
Order Code	TCC8	TCC12	TCC16
	TCC20
PVC jacket, diameter
	9.5 mm
	11.5 mm
	13.5 mm
	14.5 mm
AWG
	26
	26	26	26
No. of inner conductors
	8 x 2 x 0.14 mm?
	12 x 2 x 0.14?mm?
	16 x 2 x 0.14?mm?
	20 x 2 x 0.14?mm?
Copper strand per conductor
	18 x 0.10 mm
	18 x 0.10 mm
	18 x 0.10 mm
	18 x 0.10 mm
Conductor insulation
	PE 1.05 mm
	PE 1.05 mm
	PE 1.05 mm
	PE 1.05 mm
Shielding
AL/PT-foil + drain wire 7 x 0.15 mm? tin plated copper
	AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
	AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
	AL/PT-foil + drain wire 7 x?0.15 mm tin plated copper
Shielding factor
	100 %
	100 %
	100 %
	100 %
Temperature range?
	min. -20 ?C
	min.?-20 ?C
	min.?-20 ?C
	min.?-20 ?C
Temperature?range?
	max. 70??C
	max. 70??C
	max. 70??C
	max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
	65 pF
	65 pF
	65 pF
	65 pF
Capac. cond./shield. per 1 m
	130 pF
	130 pF
	130 pF
	130 pF
Cond. resistance per 1 m 125 m? 125 m? 125 m? 125 m?
Shield. resistance per 1 m 110 m? 110 m? 110 m? 110 m?
Technical Data
Order Code TCC24 TCC32 TCC40
PVC jacket, diameter
	16 mm
	18 mm
	20 mm
AWG
	26
	26	26
No. of inner conductors
	24 x 2 x 0.14?mm?
	32 x 2 x 0.14?mm?
	40 x 2 x 0.14?mm?
Copper strand per conductor
	18 x 0.10 mm
	18 x 0.10 mm
	18 x 0.10 mm
Conductor insulation
	PE 1.05 mm
	PE 1.05 mm
	PE 1.05 mm
Shielding
AL/PT-foil + drain wire? 7 x 0.15 mm? ?tin plated copper
	AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper
	AL/PT-foil + drain wire? 7 x 0.15 mm? tin plated copper
Shielding factor
	100 %
	100 %
	100 %
Temperature range?
	min.?-20 ?C
	min.?-20 ?C
	min.?-20 ?C
Temperature?range?
	max. 70??C
	max. 70??C
	max. 70??C
Electrical Data
Capac. cond./cond. per 1 m
	65 pF
	65 pF
	65 pF
Capac. cond./shield. per 1 m
	130 pF
	130 pF
	130 pF
Cond. resistance per 1 m	125 m?	125 m?	125 m?
Shield. resistance per 1 m	110 m?	110 m?	110 m?
	Features     
? Compact diameter
? Excellent to work with due to the use of a special AL/PT-foil
? Flexible due to the special wire construction
? Good shielding due to the overall and individual wire pair shielding
? Very good pricing
	
	Applications
? Reasonable cable for the construction of stage box systems and multi-pair systems
? Dependable cable for permanent installation in installation technologies
	
	Cable Colour
? Black
	 
| Technical Data | ||||
| Order Code | TCC8 | TCC12 | TCC16 | TCC20 | 
| PVC jacket, diameter | 9.5 mm | 11.5 mm | 13.5 mm | 14.5 mm | 
| AWG | 26 | 26 | 26 | 26 | 
| No. of inner conductors | 8 x 2 x 0.14 mm? | 12 x 2 x 0.14 mm? | 16 x 2 x 0.14 mm? | 20 x 2 x 0.14 mm? | 
| Copper strand per conductor | 18 x 0.10 mm | 18 x 0.10 mm | 18 x 0.10 mm | 18 x 0.10 mm | 
| Conductor insulation | PE 1.05 mm | PE 1.05 mm | PE 1.05 mm | PE 1.05 mm | 
| Shielding | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | 
| Shielding factor | 100 % | 100 % | 100 % | 100 % | 
| Temperature range | min. -20 ?C | min. -20 ?C | min. -20 ?C | min. -20 ?C | 
| Temperature range | max. 70 ?C | max. 70 ?C | max. 70 ?C | max. 70 ?C | 
| Electrical Data | ||||
| Capac. cond./cond. per 1 m | 65 pF | 65 pF | 65 pF | 65 pF | 
| Capac. cond./shield. per 1 m | 130 pF | 130 pF | 130 pF | 130 pF | 
| Cond. resistance per 1 m | 125 m? | 125 m? | 125 m? | 125 m? | 
| Shield. resistance per 1 m | 110 m? | 110 m? | 110 m? | 110 m? | 
| Technical Data | |||
| Order Code | TCC24 | TCC32 | TCC40 | 
| PVC jacket, diameter | 16 mm | 18 mm | 20 mm | 
| AWG | 26 | 26 | 26 | 
| No. of inner conductors | 24 x 2 x 0.14 mm? | 32 x 2 x 0.14 mm? | 40 x 2 x 0.14 mm? | 
| Copper strand per conductor | 18 x 0.10 mm | 18 x 0.10 mm | 18 x 0.10 mm | 
| Conductor insulation | PE 1.05 mm | PE 1.05 mm | PE 1.05 mm | 
| Shielding | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | AL/PT-foil + drain wire 7 x 0.15 mm tin plated copper | 
| Shielding factor | 100 % | 100 % | 100 % | 
| Temperature range | min. -20 ?C | min. -20 ?C | min. -20 ?C | 
| Temperature range | max. 70 ?C | max. 70 ?C | max. 70 ?C | 
| Electrical Data | |||
| Capac. cond./cond. per 1 m | 65 pF | 65 pF | 65 pF | 
| Capac. cond./shield. per 1 m | 130 pF | 130 pF | 130 pF | 
| Cond. resistance per 1 m | 125 m? | 125 m? | 125 m? | 
| Shield. resistance per 1 m | 110 m? | 110 m? | 110 m? | 
| SIZE | Unit: metre(s) | 
|---|
Reviews
There are no reviews yet.